Carbon accounting

Two layers: annual/average from fuel totals (camber.carbon), and hourly / marginal Scope-2 from interval electricity (camber.carbon_hourly).

Annual CO2e from fuel totals, plus hourly Scope-2 where a time-varying factor times interval load yields the timing-aware footprint.

flowchart LR
    fuel["consumption_by_fuel"] --> ann["carbon.emissions"]
    ann --> annco2["annual CO2e"]
    load["load_kw"] --> he["hourly_emissions"]
    ef["hourly_factor (kgCO2/kWh)"] --> he
    he --> eff["effective_factor + timing_premium"]
    load --> mva["marginal_vs_average"]
    avg["average_factor"] --> mva
    marg["marginal_factor"] --> mva
    mva --> gap["co2e_avg vs co2e_marginal"]

Annual — camber.carbon

emissions(consumption_by_fuel, factors=…) → CO₂e from {fuel: amount} with per-fuel factors (kgCO₂e/unit), optionally normalized per ft². The location-based, single-average-factor view.

A factor can be stated in any unit (0.93): factors={"natural_gas_therm": {"rate": 53.06, "per": "MMBtu"}} is converted exactly to kg CO₂e per therm by carbon.factor_per, through energy_units.convert_rate. A factor per gas volume needs its heat_content. No published greenhouse-gas factor set (EPA eGRID, EIA) is bundled yet; see docs/UNITS.md.

Hourly / marginal Scope-2 — camber.carbon_hourly

Grid electricity emissions vary hour to hour, so when a building uses power changes its real Scope-2 footprint. Factors are user-supplied (from a grid-signal provider); no hard-coded grid data.

Emissions against a time-varying factor — hourly_emissions

from camber.carbon_hourly import hourly_emissions

e = hourly_emissions(load_kw, hourly_factor)  # factor: kgCO2/kWh, aligned to load
e.co2e_kg, e.effective_factor, e.timing_premium_pct

The effective factor (co2e / kWh) is what the building actually incurred given its timing; the timing premium compares it to the plain time-average factor — positive when the building runs disproportionately in dirty hours, negative when it favors clean hours. unit_kg_per_kwh=False accepts a g/kWh factor.

Average vs marginal — marginal_vs_average

from camber.carbon_hourly import marginal_vs_average

c = marginal_vs_average(load_kw, average_factor, marginal_factor)
c.co2e_avg_kg, c.co2e_marginal_kg, c.marginal_over_avg

Reporting/compliance uses the average (location-based) factor; load-shift value should use the marginal factor (the emissions of the next kWh — what actually changes when you move load). Reporting both makes the gap explicit. Pairs with camber.geb.carbon_aware_shift / operation_score.