Weather fetch — NASA POWER, NOAA/ISD and Open-Meteo (camber.weather_source)

CAMBER's weather-dependent analytics — M&V weather normalization and OAT-sensor validation — need an external temperature series. Until now you brought your own (a local EPW/TMY file via mandv.weather.load_epw, or any series you already had). camber.weather_source fetches one from either of two free, keyless providers — NASA POWER (global reanalysis; the default below) and NOAA/ISD (real weather stations; see the NOAA/ISD section) — in the exact °F Series shape (name="oat_f") those consumers already accept. Since 0.92, Open-Meteo (keyless reanalysis) is a third source; see Open-Meteo.

# no API key, global coverage; returns a °F pandas Series
python - <<'PY'
from camber.weather_source import oat_reference
ref = oat_reference(34.05, -118.24, "20240101", "20240107", tz="America/Los_Angeles")
print(ref.head())
PY

API

Function Returns Use
nasa_power_url(lat, lon, start, end, *, parameters, community) str the query URL (pure, no I/O)
nasa_power_transport(*, timeout) callable(url) -> dict the default stdlib-urllib transport
fetch_nasa_power(lat, lon, start, end, *, parameters, transport, tz, timeout) DataFrame oat_f (°F) + rh_pct when requested
oat_reference(lat, lon, start, end, *, transport, tz, timeout) Series just the °F OAT reference (NaNs dropped)
cached_transport(inner, cache_dir, *, ttl, clock) callable(url) -> dict wrap any transport with an on-disk cache
geocode(address, *, transport, limit, user_agent, timeout) GeoResult address → top match (latitude, longitude, display_name)
oat_reference_for(address, start, end, *, tz, geocode_transport, transport, ...) Series geocode an address, then fetch its °F OAT
nominatim_url(address, *, limit) · nominatim_transport(*, user_agent, timeout) str · callable(url) -> dict the geocoder's URL builder + default transport
oat_reference_isd(lat, lon, start, end, *, transport, catalog_transport, tz, ...) Series NOAA/ISD station-precise °F OAT (nearest covering station)
isd_nearest_station(lat, lon, start, end, *, transport, stations, ...) IsdStation nearest ISD station covering the window
isd_stations(*, transport, timeout) · fetch_isd(usaf, wban, start, end, *, ...) list[IsdStation] · DataFrame the station catalog · one station's hourly °F
isd_transport(*, timeout) · cached_bytes_transport(inner, cache_dir, *, ttl, clock) callable(url) -> bytes the ISD default transport + its on-disk cache
oat_reference_blended(lat, lon, start, end, *, tz, transport, stations, power_transport, ...) Series provisional — ISD, gaps from the next station, the rest from bias-corrected NASA POWER (below)
power_grid_cell(lat, lon) · isd_catalog_end(stations) (lat, lon) · str provisional — the POWER cell centre · the catalog's latest station end date
isd_url(usaf, wban, year) · resolve_place(place, *, stations) str · dict provisional (0.94) — one station-year file URL · an airport code, station id or city resolved locally (privacy)

start/end accept YYYYMMDD / YYYY-MM-DD strings or date/datetime objects. parameters are NASA POWER codes (T2M = 2 m air temperature, RH2M = 2 m relative humidity). GeoResult and IsdStation are frozen values with .as_dict().

Geocoding — fetch by address, not just coordinates

NASA POWER is a lat/lon point query, so to fetch weather "for an address" you geocode it first, via OpenStreetMap Nominatim — also free and keyless:

from camber.weather_source import geocode, oat_reference_for

g = geocode("Chicago, IL")
print(g.display_name)  # "Chicago, Cook County, Illinois, United States" — confirm the match
print(g.latitude, g.longitude)

# or, one call: geocode the address then fetch its OAT reference
ref = oat_reference_for("Chicago, IL", "2024-01-01", "2024-12-31", tz="America/Chicago")

For an uncertain address, geocode first and check .display_name before fetching. The resolved place is also attached to ref.attrs["geocode"] (best-effort metadata).

  • Precision is a non-issue. NASA POWER is a ~0.5° (~50 km) reanalysis grid, so city/ZIP-level geocoding is plenty — this is a convenience, not an address-precision claim.
  • Usage policy. Nominatim requests send a descriptive User-Agent (built in) and ask for ≤ ~1 request/second with caching — so cache your lookups: cached_transport(nominatim_transport(), cache_dir) composes with geocode exactly like it does with the NASA transport.
  • Timezone still isn't derived from the address (no dependency-light lat/lon→zone) — pass the site IANA tz to oat_reference_for, the same load-bearing switch as oat_reference (below).

Timezone — read this before you join it to a sensor

NASA POWER hourly timestamps are UTC. BAS trend exports are naive local clock time (see TIME-HANDLING.md), and sensordrift.compare_to_reference aligns the two by an inner join on shared timestamps — which pandas refuses across a tz-aware/naive mismatch. So:

  • tz="UTC" (default) — the returned index is tz-aware UTC, with no hidden shift. Join it to a UTC sensor series.
  • tz="<IANA zone>" (e.g. "America/Los_Angeles") — the index is DST-correctly converted, then the tz is dropped, giving naive local civil time that inner-joins directly to a BAS trend index.

NASA's LST option is solar time, not clock time, so it would not line up with a DST-observing BAS export; this adapter deliberately does not use it. LST is the service's default, so the URL sends time-standard=UTC explicitly (before 0.90.1 it did not, and the hour keys it parsed as UTC were local solar time -- about six hours off at a US Central site), and a payload whose header says anything but UTC is refused. Getting this wrong is the one way to silently corrupt a drift bias or a normalization, so it is an explicit knob, tested for the exact hour mapping.

Two things it drops into

  • Sensor validation — feed it as the reference to sensordrift.compare_to_reference to check the site OAT sensor against what the weather actually did (bias / drift-per-month / tracking correlation) — otherwise impossible from the BAS alone.
  • M&V — a fetched series feeds mandv.weather.monthly_normals / normalized_annual_from_monthly exactly like an EPW series (same dtype, name, and index kind). NASA POWER hourly is actual reanalysis, ideal for the reporting-period actual weather; for a typical-year (TMY) normalization baseline, keep using mandv.weather.load_epw.

Requesting RH2M too lets you derive wet-bulb with coolingtower.stull_wetbulb_f(oat_f, rh_pct).

Dependency-light + offline-testable

The network call goes through an injectable transport (callable(url) -> parsed-JSON dict, default stdlib urllib — the same seam as ingest.haystack.http_json_transport). Inject your own callable to add a cache, or a canned one in tests, so every parse / unit / timezone / fill path runs with no network. No third-party dependency (stdlib urllib / json + pandas). Missing hours (NASA's -999 sentinel) become NaN rather than a bogus -999 °C; a response with no data for a parameter raises a clear ValueError.

Multi-year requests

NASA POWER caps a single hourly request at ~1 year, but fetch_nasa_power handles that transparently: it splits [start, end] into consecutive calendar-year chunks (one call per year), then concatenates them into a single, unique, sorted hourly index. A three-year request "just works" — no extra argument. Calendar-year seams share no day (one chunk ends Dec-31, the next starts Jan-01), so no hour is duplicated or dropped.

On-disk cache

cached_transport(inner, cache_dir) wraps any transport with a dependency-light on-disk cache, so repeated fetches don't re-hit the API — and, combined with year-chunking, a re-run only downloads the years missing from disk:

from camber.weather_source import fetch_nasa_power, nasa_power_transport, cached_transport

transport = cached_transport(nasa_power_transport(), "/var/cache/camber-weather")
df = fetch_nasa_power(34.05, -118.24, "20200101", "20231231", transport=transport)

Each URL's parsed JSON is memoized to <cache_dir>/<sha256(url)>.json with an atomic write; a corrupt file self-heals (treated as a miss). NASA POWER historical reanalysis is stable, so the default is cache-forever; the most recent ~months can be revised, so pass a ttl (a datetime.timedelta) for windows that touch recent data. clock is injectable for deterministic TTL tests.

NOAA/ISD station data (a second, station-precise provider)

NASA POWER is a global reanalysis on a ~0.5° (~50 km) grid. When you want a real weather station near the site, camber.weather_source also fetches NOAA's Integrated Surface Database (ISD-Lite) — also keyless. oat_reference_isd finds the nearest station covering your window and returns the same °F oat_f Series:

from camber.weather_source import oat_reference_isd, isd_nearest_station

st = isd_nearest_station(41.88, -87.63, "2023-01-01", "2023-12-31")
print(st.name, st.usaf, st.wban)  # confirm the station it picked

ref = oat_reference_isd(41.88, -87.63, "2023-01-01", "2023-12-31", tz="America/Chicago")
# ref -> °F Series (name "oat_f"); the resolved station is on ref.attrs["isd_station"]

Station-precise but gappy — the honest trade-off. ISD is a point measurement at a real station, higher spatial fidelity than NASA's grid when a station is nearby — but it is gappy (stations go offline; missing hours are common → dropped to NaN) and sparse (no station near remote sites; coverage windows vary — isd_nearest_station filters to stations whose record spans your window and raises if none does). So: ISD when a nearby station covers the window and you want station fidelity; NASA POWER for global coverage, a gap-free series, or anywhere without a station. They complement.

  • Endpoints (keyless): the station catalog https://www.ncei.noaa.gov/pub/data/noaa/isd-history.csv (~5 MB) and per-station-per-year gzipped hourly files under .../isd-lite/. Air temp is tenths of °C; the -9999 missing sentinel → NaN.
  • Timezone is the same load-bearing switch as the NASA path (pass the site IANA tz; see above).
  • Caching. ISD uses a bytes transport (gzipped/CSV, not JSON), so it has its own cache decorator — cached_bytes_transport(isd_transport(), cache_dir). Cache the 5 MB catalog, or resolve the station list once with isd_stations() and pass it to isd_nearest_station(..., stations=…).
  • A missing year no longer aborts. A station-year file that does not exist (HTTP 404, which happens even inside the catalog's coverage) is skipped with a warning and listed in frame.attrs["isd_missing_years"]; fetch_isd(..., on_missing_year="raise") restores the abort. cached_bytes_transport remembers a 404, so an offline re-run sees the same gap.
  • A stale catalog is named. When no station covers a window that ends after the catalog's latest station end date, isd_nearest_station warns that the catalog looks stale and says so in its error.

ISD with a NASA POWER fallback (provisional)

oat_reference_blended (or oat_reference_isd(..., fallback="nasa_power")) returns the same oat_f Series, but does not fail when the ISD catalog ends before your window or one station-year is missing:

  1. Stations. Up to max_stations (3) stations within max_distance_km (100 km), nearest first. A station still reporting when the catalog was built is tried past its catalog end date, in case only the catalog is stale. The nearest station that returns data is the reference and fills the window. Each later one fills only runs of at least gap_hours (24) missing hours. Since 0.92 it is first offset-corrected against the reference: the same monthly and hour-of-day correction as below, estimated over the hours both stations report (station_offsets=False turns this off).
  2. NASA POWER fills what is still missing, read at the snapped grid cell (power_grid_cell: the 0.5° × 0.625° cell centre, so every point in a cell shares one URL and one cache entry). POWER lags real time by days to weeks and returns not-yet-published trailing hours as fill: those stay missing, never data, and the last real hour is reported as the coverage end.
  3. Bias correction. POWER is corrected against the reference station (the nearest one with data) by a monthly mean offset, station − POWER, over the hours both carry in [min(start, end − overlap_days), end] (overlap_days = 365). A calendar month with at least 240 paired hours (~10 days, pooled across years) gets its own offset; otherwise its meteorological season's (DJF/MAM/JJA/SON, at least 240 pairs); otherwise one offset over all pairs (at least 168); otherwise none, and the caveat says UNCORRECTED. Since 0.92 an hour-of-day step follows (diurnal=True, the default). What the monthly offset leaves is averaged per (season, UTC hour), where a cell has at least 30 pairs; otherwise per UTC hour over all seasons; otherwise 0. Reanalysis damps the daily cycle (warm nights, cool afternoons), and a monthly offset cannot remove that. Each cell's residual averages zero, so the monthly and daily means do not move. The RMSE of the paired hours is recorded before (rmse_before_f), after the monthly step (rmse_after_monthly_f) and after both (rmse_after_f).
  4. Provenance. series.attrs["weather_provenance"] holds the stations tried (distance, missing years, hours filled), the per-source date segments (isd:<usaf>-<wban>, nasa_power, missing), the POWER cell and coverage end, the bias_correction (offsets, basis per month, pair counts, RMSE) and the caveats, which are also on series.attrs["caveats"]. Any fallback raises one UserWarning with the same text.

cache_dir= caches every source. A POWER or Open-Meteo response whose trailing hours are not yet published is not cached, so it is re-fetched once it is. With offline=True only the cache is read, and a miss raises WeatherCacheMiss, so a re-run is reproducible without the network.

How much the corrections help (0.92)

The measure is out of sample: each correction was estimated on 2022-2023 and tested on 2024, at three public airports with a second ISD station 3-22 km away. The table gives the hourly RMSE against the airport station, in °F:

Site Source Raw Monthly offset + hour of day
Chicago O'Hare NASA POWER 4.67 3.83 2.86
Open-Meteo 3.35 2.60 2.31
nearby station 2.11 1.99 1.96
Phoenix Sky Harbor NASA POWER 7.30 5.85 2.99
Open-Meteo 4.27 2.99 2.72
nearby station 3.68 2.04 1.95
Boston Logan NASA POWER 4.98 4.20 3.43
Open-Meteo 2.99 2.82 2.59
nearby station 1.67 1.45 1.32

The daily-mean RMSE (1.2-2.1 °F) is the same with or without the hour-of-day step, which leaves daily means alone by design. The step matters for hourly uses (sensor-drift checks, hourly models, degree-hours), not for daily or billing M&V. For those the monthly offset is the correction that counts.

The fallback order, and one entry point

oat_reference_blended(..., fallbacks=("nasa_power",)) is the 0.90.1 behaviour and stays the default. fallbacks=("nasa_power", "open_meteo") fills whatever POWER leaves (its publication lag, a failed request) from Open-Meteo, which is corrected the same way. A source whose request fails is recorded in weather_provenance["fallbacks"] and the next one is tried. With a single fallback, a failure is still raised. Each fallback's grid cell, coverage end, hours filled and bias_correction are recorded there, and POWER's also stay under power / bias_correction.

oat_reference_auto(lat, lon, start, end, source=...) picks the source by name:

source What it returns
"auto" ISD, offset-corrected neighbouring stations, then NASA POWER, then Open-Meteo
"isd" ISD stations only (gap-filled, offset-corrected)
"nasa_power" NASA POWER alone, uncorrected
"open_meteo" Open-Meteo alone, uncorrected

A config reaches it in two places: - the RCx report's oat_reference ({"fetch": "auto", "latitude", "longitude", "tz", "cache_dir", "offline"}), where the report lists the hours from each source and the fallback caveats under the OAT comparison. {"fetch": "nasa_power"} still means POWER alone; - an mv billing entry's oat (see MANDV.md).

Weather requests carry coordinates and dates only: no key, account or other identifier. For a non-public site, coarsen or drop even the coordinates: see Privacy.

Open-Meteo, a third source (provisional, 0.92)

fetch_open_meteo(lat, lon, start, end) reads Open-Meteo's historical-weather API (archive-api.open-meteo.com): hourly 2 m temperature in °F, UTC, from its best_match reanalysis (ERA5 and higher-resolution companions; pass models= to choose one). The frame's attrs carry the grid point (coordinates and elevation) as open_meteo_cell, and open_meteo_coverage_end. oat_reference_open_meteo returns the oat_f series. Requests are one per calendar year, through the same injectable JSON transport as POWER (open_meteo_transport, cached_transport). null hours are missing, never data. A payload not in UTC, or in an unknown unit, is refused.

Like POWER it is gridded, not a station, so in the blend it is a fallback, bias-corrected against the reference station. In the table above its raw error is lower than POWER's. Terms. Open-Meteo's data are licensed CC BY 4.0: attribute "Weather data by Open-Meteo.com" where you publish them. Its free API is for non-commercial use under its terms of service, within limits (fewer than 10,000 calls a day). Commercial use needs one of its subscriptions or a self-hosted instance. The reanalysis itself comes from the Copernicus Climate Change Service. These terms were checked on open-meteo.com on 2026-09-27. CAMBER only sends the request, and whether your use is covered is for you to check.

Privacy: weather for non-public sites (provisional, 0.94)

A weather request says where the building is: a latitude and longitude to five decimals locate one roof. For client data, CAMBER can still use real weather under guardrails that decide, by construction, what leaves the machine (camber.weather_privacy, issue #73).

The three modes

privacy Network What each request carries
"public" yes the coordinates as given (the behaviour before 0.94, and still the default)
"coarse" yes coarsened locations only: ISD a station id and a year, NASA POWER a grid-cell centre, Open-Meteo the point rounded to precision_deg
"offline" none nothing: caches and weather files you supply

Set it for a config, or for one fetch:

{"site": "...", "facility_id": "...",
 "weather": {"privacy": "coarse", "precision_deg": 0.1},
 "mv": [{"bills": {"file": "gas.csv"},
         "oat": {"fetch": "auto", "place": "KORD", "tz": "America/Chicago",
                 "cache_dir": "wx"}}]}

A fetch's own weather block (in an mv entry's oat, or in report.rcx.oat_reference) overrides the config's.

How each source is coarsened.

  • NOAA ISD. The station is chosen locally, from the downloaded station catalogue (isd-history.csv). That download is one fixed URL with no query, so it carries nothing about the site. After that, each request is one station-year file, .../isd-lite/<year>/<usaf>-<wban>-<year>.gz. No coordinates are in any ISD request.
  • NASA POWER. The point snaps to the centre of its POWER grid cell before the URL is built. POWER's meteorology comes from MERRA-2 on a "½° latitude by ⅝° longitude grid" (POWER data sources, checked 2026-09-28), about 55 km × 50 km at 42° N. POWER returns that cell for any point inside it, so snapping loses nothing. The cache key is the cell.
  • Open-Meteo. The point is rounded to precision_deg, 0.1° by default. The rounding moves it at most 0.05°, about 5.6 km north-south and 4.1 km east-west at 42° N. The request therefore names an area of about 11 km × 8 km there: a town or a district of a city, not a building. ERA5 (0.25°, about 25 km) and ERA5-Land (0.1°, about 9 km) resolve no finer, and Open-Meteo's higher-resolution models only a little finer. The finest precision accepted is 0.05°. The cache key is the rounded cell.
  • Geocoding (Nominatim) sends the address itself, so it is refused under coarse and offline. Name the location without coordinates instead, resolved on your machine: "place": "KORD" (an airport ICAO code, looked up in the ISD catalogue), "place": "725300-94846" (an ISD station id), or "place": "Chicago, IL" (a bundled table of about 80 major cities, camber.weather_privacy.CITY_TABLE). A code needs the catalogue; a city does not.

Under coarse and offline the cache lives in cache_dir, else in $CAMBER_WEATHER_DIR, else in $XDG_CACHE_HOME/camber/weather (by default ~/.cache/camber/weather). Caches are keyed by the request URL, which holds the station, the cell or the rounded point, so one cache serves every facility in that cell and never names a facility.

Offline makes no network call at all. A cache miss raises WeatherCacheMiss, and an mv billing entry declines with the reason, which says how to supply the data. Give a point CSV ("oat": {"file": "oat.csv"} or the config's shared_oat), or the RCx report's "oat_reference": {"csv": ...}. You can also fill the cache once under coarse. After that, an offline re-run reads the same cells and gives the same series.

Private facilities

A facility is private when its portfolio registry entry says so (camber facility add --private, or camber facility private ID --reason ...), or when its config says "private": true. Either is enough.

  • A private facility's weather fetches default to offline. The user opts in with "weather": {"privacy": "coarse"}.
  • A private facility can never be public: that config is refused.
  • EIA and URDB requests follow the same policy.

The flag belongs in the registry because it describes the facility, not one analysis. It then holds for every config that names the facility, including ones written later. Changing it is an audited admin action with a reason. The config flag covers runs outside a portfolio workspace, and it can only make a facility stricter.

The audit log

Every outbound request is appended to an audit log, whatever the privacy mode. It covers weather, the EIA price check and a URDB tariff. Cache hits and offline misses are logged too, as "sent": false. Inside a portfolio workspace the log is state/<facility_id>/weather_audit.ndjson. Outside one, it is weather_audit.ndjson next to the cache. A public fetch with neither a workspace nor a cache_dir is not logged.

{"ts": "2026-09-28T10:00:00Z", "service": "nasa_power", "privacy": "coarse",
 "url": "https://power.larc.nasa.gov/api/temporal/hourly/point?parameters=T2M&community=RE&latitude=42.0&longitude=-87.5&start=20240101&end=20241231&format=JSON&time-standard=UTC",
 "purpose": "M&V billing weather", "cache": "miss", "sent": true, "facility_id": "office-a"}

The url is the URL as sent, except that an API key is replaced by REDACTED. EIA's key is added by the live transport after the check, so it never appears in the log. The facility id appears in the local record only, never in a URL.

camber weather audit [--facility ID] [--since YYYY-MM-DD] [--workspace PATH] [--cache-dir DIR] [--file F] [--json]

Enforced, not just intended

coarsen(service, lat, lon, policy) is the only function that turns a location into request coordinates. The URL builders (nasa_power_url, open_meteo_url) call it. Independently, every request under coarse or offline passes check_url before it leaves. The check refuses:

  • a POWER coordinate off the POWER grid, or an Open-Meteo coordinate finer than precision_deg;
  • any coordinate in an ISD request;
  • a query field the service does not need, or a value longer than a short code or number;
  • a host other than the service's;
  • under offline, any request at all.

A refusal raises PrivacyViolation and nothing is sent.

Provenance

A fetched series records what was sent. attrs["weather_privacy"] (and, for the ISD blend, also weather_provenance["privacy"]) holds:

  • the mode, the precision and where the policy came from;
  • the coarsening applied to each source;
  • the number of requests sent and served from the cache.

The rest of the provenance is unchanged: the source of every hour, the station, the POWER or Open-Meteo cell, and the bias correction. See SECURITY.md for the full list of what is sent and what never is.